ArticleBiz.com :: Free article content
Authors: Maximum article exposure. Publishers: Reprintable article content.  
BROWSE ARTICLES
ArticleBiz.com Home
Featured Articles
Recently Added Articles
Most Viewed Articles
Article Comments
Advanced Article Search
AUTHORS
Submit Article
Check Article Status
Author TOS
PUBLISHERS
RSS Article Feeds
Terms of Service

Dental Instument Sterilization
Home :: Health & Fitness
By: Steven Brazis Email Article
Word Count: 608 Digg it | Del.icio.us it | Google it | StumbleUpon it

  

The Centers for Disease Control Guidelines for Infection Control in Dental Health-Care Settings was issued in 2003 for the education of dental personnel regarding infection control. It is intended to prevent the transmission of bloodborne pathogens.

This comprehensive document covers: hand hygiene, personal protective equipment, contact dermatitis/latex allergy, disinfection/sterilization, environmental infection control, waterlines/biofilms and special dental considerations such as hand pieces, radiographs and laboratory procedures.

The CDC's Guidelines for Infection Control in Dental Settings are evidenced based and well documented. The sterilization of dental instruments is one of the main areas of concern in dental offices. Along with the proper sterilization of instruments and materials, sterilizer monitoring is an essential part of the infection control program.

Many factors can cause sterilization to fail--from procedural errors that are easily remedied, like overloading, to mechanical problems that can take a sterilizer out of service until repairs can be made. Since this variety of factors can influence successful sterilization, the CDC and the American Dental Association encourage dentists to regularly assess the efficiency of their in-office sterilizers.

Sterilization should be monitored using both chemical and biological indicators. Chemical indicators, such as indicator tapes, are to be used with each instrument load. A color change of these indicators reveals exposure to the proper sterilization conditions.

Failure of the indicator to change color indicates that it was not exposed to the proper sterilization environment (e.g., proper pressure or temperature). In such cases, the instrument load should be re-sterilized. Indicator tapes are made specifically for certain types of sterilizers (i.e., tapes for steam sterilizers cannot be used to test chemical vapor sterilizers). Chemical indicators should not replace biological indicators, as only a biological indicator consisting of bacterial endospores can measure the microbial killing power of the sterilization process.

The CDC and ADA both recommend that sterilizers be monitored at least weekly with biological indicators. Each state dental board may actually have a requirement for biological monitoring.

Biological monitoring can be done in two ways. In-office incubator and spore monitoring strips can be purchased from dental supply houses. This method usually gives results in 24-48 hours. Mail-in spore monitoring programs are also available. This process usually takes a week. Although it takes longer to get results, mail-in monitoring programs may be more reliable and credible than in-house monitoring. A log of spore test results should be maintained in the dental office, usually in the sterilization area.

A positive test using chemical or biological indicators signifies that sterilization failed. If the chemical indicator does not change color or the spore test result is positive, the following steps are recommended. The sterilizer should be taken out of service. Instruments that were used after the last documented negative spore test should not be used. The sterilization process being followed in the office should be reviewed to rule out operator error as the cause of failure.

Page 1 of 2 :: First | Last :: Prev | 1 2 | Next

Dr. Steven Brazis has practiced family and cosmetic dentistry for 35 years. His practice is in Sacramento, CA. He has written extensively on dentistry for the lay person. His web site is: http://www.toothhaven.com

Article Source: http://www.ArticleBiz.com

This article has been viewed 50 times.

Rate Article
Rating: 0 / 5 stars - 0 vote(s).

Article Comments
There are no comments for this article.

Leave A Reply
 Your Name
 Your Email Address [will not be published]
 Your Website [optional]
 What is five + nine? [tell us you're human]
Notify me of followup comments via email


Related Articles


Copyright © 2008 by ArticleBiz.com. All rights reserved.

Terms of Service | Privacy Policy | Contact Us | Submit Article | Editorial